| Property | Specification Requirement | Test Method | Test Value |
|---|---|---|---|
| Tensile Strength | ≥16MPa | ASTM D2671 | ≥19.5MPa |
| Elongation at Break | ≥200% | ASTM D2671 | ≥450% |
| Tensile Strength After Aging | ≥11.5MPa | ASTM D2671 (136°C/168 hours) |
≥15MPa |
| Elongation at Break After Aging | ≥100% | ASTM D2671 (136°C/168 hours) |
≥200% |
| Voltage Withstand | AC2500V/60SNo damage | ASTM D2671 | No damage |
| ภาวะช็อกจากความร้อน | No cracking | ASTM D2671 (250°C/4 hours) |
No cracking |
| Volume Resistivity | ≥10^14 Ω·cm | ASTM D2671 | ≥10^14 Ω·cm |
| Copper Stability | No corrosion | ASTM D2671 (136°C/168 hours) |
No corrosion |
| Product Code | Before Shrinking(mm) | After Shrinking (mm) | Standard Length (m) | ||
|---|---|---|---|---|---|
| Inside Diameter(Min.) | Wall Thickness | Inside Diameter (Max.) | Wall Thickness (Min.) | ||
| ABS48 | 4.8±0.3 | 0.50±0.15 | 1.6 | 1.10±0.15 | 100 |
| ABS58 | 5.8±0.3 | 0.55±0.15 | 1.9 | 1.30±0.15 | 100 |
| ABS68 | 6.8±0.3 | 0.60±0.15 | 2.4 | 1.35±0.15 | 100 |
| ABS70 | 7.0±0.3 | 0.60±0.15 | 2.5 | 1.35±0.15 | 100 |
| ABS80 | 8.0±0.3 | 0.70±0.15 | 3.0 | 1.45±0.15 | 50 |