| Property | Specification Requirement | Test Method | Test Value |
|---|---|---|---|
| Tensile Strength | ≥10.3MPa | ASTM D2671 | ≥21MPa |
| Elongation at Break | ≥200% | ASTM D2671 | ≥550% |
| Tensile Strength After Aging | 70% of initial value | ASTM D2671 (158°C/168 hours) |
≥70% |
| Elongation at Break After Aging | ≥100% | ASTM D2671 (158°C/168 hours) |
≥524% |
| Voltage Withstand | AC2500V/60SNo damage | ASTM D2671 | No damage |
| Volume Resistivity | ≥10^13 Ω·cm | ASTM D2671 | ≥10^13 Ω·cm |
| Copper Stability | No corrosion | ASTM D2671 (158°C/168 hours) |
No corrosion |
| Product Code | Before Shrinking(mm) | After Shrinking (mm) | Standard Length (m) | |
|---|---|---|---|---|
| Inside Diameter(Min.) | Inside Diameter (Max.) | Wall Thickness (Min.) | ||
| AOS06 | 6.0 | 1.5 | 1.5 | 1.22 |
| AOS08 | 8.0 | 2.0 | 1.5 | 1.22 |
| AOS12 | 12.0 | 3.0 | 2.3 | 1.22 |