| Property | Specification Requirement | Test Method | Test Value |
|---|---|---|---|
| Tensile Strength | ≥10.4MPa | ASTM D2671 | ≥16.9MPa |
| Elongation at Break | ≥200% | ASTM D2671 | ≥362% |
| Voltage Withstand | AC2500V/60SNo damage | ASTM D2671 | No damage |
| Volume Resistivity | ≥10^16 Ω·cm | ASTM D2671 | ≥10^16 Ω·cm |
| Product Code | Size(mm) | Before Shrinking(mm) | After Shrinking (mm) | Standard Length (m) | ||
|---|---|---|---|---|---|---|
| Inside Diameter | Wall Thickness | Inside Diameter (Max.) | Wall Thickness (Min.) | |||
| GA-0030 | 3.0 | 3.6±0.3 | 0.15 | 1.8 | 0.40±0.15 | 200 |
| GA-0035 | 3.5 | 4.1±0.3 | 0.15 | 2.0 | 0.40±0.15 | 200 |
| GA-0040 | 4.0 | 4.6±0.3 | 0.15 | 2.3 | 0.40±0.15 | 200 |
| GA-0050 | 5.0 | 5.9±0.3 | 0.15 | 2.9 | 0.40±0.15 | 100 |
| GA-0060 | 6.0 | 6.5±0.3 | 0.20 | 3.5 | 0.50±0.15 | 100 |
| GA-0070 | 7.0 | 7.5±0.3 | 0.20 | 4.2 | 0.50±0.15 | 100 |
| GA-0080 | 8.0 | 8.5±0.3 | 0.20 | 4.7 | 0.50±0.15 | 100 |
| GA-0090 | 9.0 | 9.5±0.3 | 0.20 | 5.4 | 0.50±0.15 | 100 |
| GA-0100 | 10.0 | 10.5±0.4 | 0.20 | 6.0 | 0.50±0.15 | 100 |
| GA-0110 | 11.0 | 11.5±0.4 | 0.20 | 7.0 | 0.50±0.15 | 100 |
| GA-0120 | 12.0 | 12.4±0.4 | 0.23 | 7.6 | 0.60±0.15 | 100 |
| GA-0130 | 13.0 | 13.4±0.4 | 0.23 | 8.0 | 0.60±0.15 | 100 |
| GA-0140 | 14.0 | 14.4±0.4 | 0.23 | 9.0 | 0.60±0.15 | 100 |
| GA-0150 | 15.0 | 15.4±0.5 | 0.23 | 10.0 | 0.60±0.15 | 100 |
| GA-0160 | 16.0 | 16.4±0.4 | 0.23 | 10.5 | 0.60±0.15 | 100 |
| GA-0180 | 18.0 | 18.4±0.4 | 0.23 | 11.5 | 0.60±0.15 | 100 |
| GA-0200 | 20.0 | 20.4±0.4 | 0.23 | 13.0 | 0.60±0.15 | 100 |
| GA-0220 | 22.0 | 22.4±1.0 | 0.23 | 14.0 | 0.60±0.15 | 100 |
| GA-0250 | 25.0 | 25.5±1.0 | 0.23 | 15.0 | 0.60±0.15 | 50 |